상세 보기
표준석탄화력 발전소 해수온도 상승에 따른 복수기 압력 손실 최소화 방안
- 안효열;
- 문승재
초록
In this paper, studied condenser operating management which is affecting power plants efficiency considering the cost of poor quality. Sea water temperature and condenser pressure have clear correlation in S power plants. As the sea water temperature changes, condenser pressure changed -1.7~+20 mmHg from design condenser pressure(38.1 mmHg). Use the heat rate correction curve from manufactory company, realized that efficiency and cost of poor quality changed 0.0201%, 12,830 won/h at Unit #1,2 but 0.0155%, 9,832 won/h when condenser pressure 1 mmHg rise. Also, checked that it is changed depend on seasonal corresponding operation, plant ageing and the point of preventive maintenance like overhaul maintenance. This study said if we considered complying with management range and planning overhaul maintenance, then it could help reducing operating maintenance losses minimum 2.5 billion won per 1 year (case : Unit #1, forty days maintenance).
키워드
- 제목
- 표준석탄화력 발전소 해수온도 상승에 따른 복수기 압력 손실 최소화 방안
- 제목 (타언어)
- A Study on Minimizing of Condenser Pressure Loss according to the Temperature Rise of the Seawater for Korean Standard Coal-fired Power Plants
- 저자
- 안효열; 문승재
- 발행일
- 2015-06
- 유형
- 정기학술지(Article(Perspective Article포함))
- 저널명
- 플랜트 저널
- 권
- 11
- 호
- 2
- 페이지
- 45 ~ 51