상세 보기
Capacity evaluation of repaired structural walls having special detailing for moderate seismic zone
- Han, S.W.;
- Lee, Y.M.;
- Oh, C.H.;
- Lee, L.H.
SCOPUS
0초록
objective of this study is to investigate the seismic performance of repaired structural walls. The structural walls under consideration have specific details that have been widely used in Korea. In this study three isolated largescale wall specimens were made. After testing, all specimens were repaired. The aspect ratio under consideration is I to 3. Because of the space limitation of the laboratory the dimensions of all walls are the same. The aspect ratio was controlled by the combination of axial and lateral forces using the special test setting. The walls were tested using the incremental pseudo static cyclic loads until failure occurs. After that, only the damaged regions are repaired using a concrete with the same properties of the original concrete. The sectional area was unchanged after repairing. The severely yielded reinforcements were replaced by new reinforcement having the same sectional area and properties. Also, epoxy resins were used to Jill the cracks in the damaged walls. From this study the capacities of repaired structural walls with specific details after severely damaged is evaluated and compared with those of the corresponding original specimens.
키워드
- 제목
- Capacity evaluation of repaired structural walls having special detailing for moderate seismic zone
- 저자
- Han, S.W.; Lee, Y.M.; Oh, C.H.; Lee, L.H.
- DOI
- 10.14359/9962
- 발행일
- 2000-09
- 유형
- Conference Paper
- 저널명
- American Concrete Institute, ACI Special Publication
- 권
- 193
- 페이지
- 821 ~ 834