Improved measurement method for electron energy distribution functions with high accuracy and reliability

Citations

WEB OF SCIENCE

20
Citations

SCOPUS

21

초록

An improved ac superimposed method for measuring the electron energy distribution function (EEDF) with high accuracy is proposed. Although high amplitude of the superimposed ac voltage provides a higher signal-to-noise ratio (SNR), it causes the distortion in the EEDF. To correct the distortion, we used two different EEDFs measured by applying two different amplitudes. The distortion was accurately corrected over the entire electron energy region, and the corrected EEDF had the better SNR. The reliability of the corrected EEDF was proved by comparing the effective electron temperatures obtained from the measured EEDFs, and as a result, the corrected EEDF was very reliable.

키워드

LANGMUIR PROBEPLASMAS
제목
Improved measurement method for electron energy distribution functions with high accuracy and reliability
저자
Bang, Jin YoungKim, AramChung, Chin Wook
DOI
10.1063/1.3432118
발행일
2010-06
유형
Article
저널명
Physics of Plasmas
17
6
페이지
1 ~ 4