Noninvasive method to measure the ion flux in capacitive discharge

Citations

WEB OF SCIENCE

6
Citations

SCOPUS

6

초록

A noninvasive method to measure the ion flux from the current flowing through the substrate (substrate current) in a capacitive discharge is proposed. The substrate current consists of a displacement current and a conduction current. In a high frequency capacitively coupled plasma, the displacement current is usually much higher than the conduction current. However, the displacement current becomes negligible at a moment that the second time derivative of the substrate current becomes zero (the first time derivative reaches its minimum), and from the measured substrate current at that time, the ion flux can be obtained. The measured ion flux from this method is compared with the flux measured by another diagnostic method.

키워드

DENSITYPROBE
제목
Noninvasive method to measure the ion flux in capacitive discharge
저자
Lee, Min-HyongLee, Hyo-ChangChung, Chin-Wook
DOI
10.1063/1.2815923
발행일
2007-11
유형
Article
저널명
Applied Physics Letters
91
22
페이지
1 ~ 4