Improvement of Crack Sizing Performance by using Nonlinear Ultrasonic Technique

  • Seo, Hogeon
  • Jhang, Kyung-Young
  • Kim, Kyung-Cho
  • Hong, Dong-Pyo
Citations

WEB OF SCIENCE

8
Citations

SCOPUS

8

초록

The nonlinear ultrasonic technique (NUT) based on the contact acoustic nonlinearity (CAN) has been considered as a promising method for the closed crack detection. However, most of the previous studies were limited to the modeling of the second-order harmonic wave generation at contacted interfaces and its verification by testing artificially contacted interfaces in the through-transmission method. In this study, we investigated experimentally the contact acoustic nonlinearity at a real crack by using the measurement system constructed in the pitch-catch method that permits the transducers to access the only single side of a test structure. Results showed that the magnitude of the second-order harmonic wave represented the existence of the closed area clearly and that the crack sizing performance was greatly improved by the combination of the linear and nonlinear ultrasonic techniques.

키워드

Crack sizingContact interfaceContact Acoustic Nonlinearity (CAN)Harmonic wave generationPitch-catch methodHARMONIC-GENERATIONINTERFACESWAVESPROPAGATIONSURFACESCONTACT
제목
Improvement of Crack Sizing Performance by using Nonlinear Ultrasonic Technique
저자
Seo, HogeonJhang, Kyung-YoungKim, Kyung-ChoHong, Dong-Pyo
DOI
10.1007/s12541-014-0614-4
발행일
2014-11
유형
Article
저널명
International Journal of Precision Engineering and Manufacturing
15
11
페이지
2461 ~ 2464