유전 센서 및 광섬유 센서를 이용한 EMC 유효 경화 수축 측정

Measurement of effective cure shrinkage of EMC using dielectric sensor and FBG sensor

초록

Recently, as the thickness of the semiconductor package becomes thinner, warpage has become a major issue. Since the warpage is caused by differences in material properties between package components, it is essential to precisely evaluate the material properties of the EMC(Epoxy molding compound), one of the main components, to predict the warpage accurately. Especially, the cure shrinkage of the EMC is generated during the curing process, and among them, the effective cure shrinkage that occurs after the gelation point is a key factor in warpage. In this study, the gelation point of the EMC was defined from the dissipation factor measured using the dielectric sensor during the curing process similar with actual semiconductor package. In addition, DSC (Differential scanning calorimetry) test and rheometer test were conducted to analyze the dielectrometry measurement. As a result, the dielectrometry was verified to be an effective method for monitoring the curing status of the EMC. Simultaneously, the strain transition of the EMC during the curing process was measured using the FBG (Fiber Bragg grating) sensor. From these results, the effective cure shrinkage of the EMC during the curing process was measured.

키워드

EMC (Epoxy molding compound)Cure shrinkageGelation pointDielectrometryFBG (Fiber Bragg grating) sensor
제목
유전 센서 및 광섬유 센서를 이용한 EMC 유효 경화 수축 측정
제목 (타언어)
Measurement of effective cure shrinkage of EMC using dielectric sensor and FBG sensor
저자
백정현박동운김학성
DOI
10.6117/kmeps.2022.29.4.083
발행일
2022-12
저널명
마이크로전자 및 패키징학회지
29
4
페이지
83 ~ 87

파일 다운로드