Real time thickness measurement based on terahertz time-domain spectroscopy for chip-top epoxy molding compound in semiconductor package

  • Oh, Gyung Hwan
  • Park, Dong Woon
  • Kim, Dug Joong
  • Kim, Hak Sung
Citations

SCOPUS

0

초록

The refractive index and thickness of EMC were measured non-destructively using the terahertz time-domain spectroscopy (THz-TDS) system. A theoretical model was developed using an analysis of time response on transmission and reflection THz signals. Using this developed theoretical model, the refractive index of EMC was measured within 1% of the error range. Simultaneously, the thickness of EMC was calculated through the measured refractive index and induced time delay. As a result, the refractive index and thickness of EMC was measured within the error range of 0.9% and 3.0%, respectively.

키워드

Electronics packagingPlasmonsReflectometersRefractive indexSpectrophotometersTerahertz wavesThickness measurementEpoxy molding compoundsError rangeReal timeSemiconductor packagesTerahertz time domain spectroscopyTheoretical modelingTHz signalTerahertz spectroscopy
제목
Real time thickness measurement based on terahertz time-domain spectroscopy for chip-top epoxy molding compound in semiconductor package
저자
Oh, Gyung HwanPark, Dong WoonKim, Dug JoongKim, Hak Sung
DOI
10.1109/IRMMW-THz.2018.8510029
발행일
2018-10
유형
Proceeding
저널명
International Conference on Infrared, Millimeter, and Terahertz Waves, IRMMW-THz
2018
September